Capacity: 250,000 - 500,000 lb/hr
Fuel Capabilities: Digestor Gas, Fuel Oil, Hydrogen, Natural Gas, Other Fuels
Steam Design Pressure: Up to 1,200 psig
Resources
General Description
Tandem Steam Generating Units-Type Boiler with separate furnace, convection, and superheater module.
Features
- Superheated steam temperature up to 900°F
- Patented design incorporates separate furnace, convection, and superheater module
- Suitable for Natural gas, Oil, and Heat Recovery applications
- Lower cost of ownership: minimized capital cost and reduced operating costs
Construction
- Separate Furnace, Convection and Superheater modules for easy transportation
- Enlarged furnace with uniform heat flux promotes lower emissions
- 100% Water cooled wall construction
- Generous convection module with lowest total draft losses
- Optional superheater module
- Gas outlet configuration: top, rear, left, or right side
Quality
100% Furnace water-cooled membrane wall construction
Air-tight full membraned front, rear, and side exterior walls
0.25″ thick membrane fin plate
All drilled drum holes are grooved
Minimum tube thickness exceeds ASME requirements:
– 0.105″ min. wall convection tubes
– 0.120″ min. wall furnace tubes
Economizer designed and built by Superior
All ladders and platforms are fit and bolted to boiler then disassembled for shipment
Safety